0 3 up AC up 18880 643.0
Dell#show environment fan
-- Fan Status --
Unit Bay TrayStatus Fan0 Speed Fan1 Speed
------------------------------------------------------
0 0 up up 5263 up 5292
0 1 up up 5274 up 5317
0 2 up up 5256 up 5292
0 3 up up 5278 up 5328
0 4 up up 5270 up 5320
Speed in RPM
Dell#show environment thermal-sensors
-- Thermal Sensor Readings (deg C) --
Module S0 S1 S2 S3 S4 S5 S6 S7 S8 S9 S10
---------------------------------------------------------------
System Core 33 33 34 33 28 39 25 36 39 39 -
Switching Core 100[M] 46 47 45 44 45 - - - - -
Port Modules 49 101[M] 60 49 62 52 78 55 53 50 46
Threshold crossed [m]: minor [M]: major, [S]: shutdown
Example (PE
Console)
Dell#show environment stack-unit
-- Unit Environment Status --
Unit Status Temp Voltage
------------------------------------
* 1 online 28C ok
* Management Unit
show inventory
Display the switch type, components (including media), and Dell Networking OS version, including hardware identification numbers and
configured protocols.
C9000 Series
Syntax
show inventory [media [slot-id | pe pe-id [stack-unit unit-number]]| pe pe-id]]
From a PE console, use show inventory [media] to view the PE inventory information.
Parameters
media
slot-id
(OPTIONAL) Enter the keyword media to display pluggable media inventory for a
specified line-card slot. Valid slot IDs are from 0 to 2.
pe
pe-id
(OPTIONAL) Enter the keyword pe to display port extender (PE) inventory for a
specified PE ID. Range is from 0 to 255.
NOTE: The pe option is only available when the extended bridge feature is
enabled.
Defaults none
Command Modes CONFIGURATION
Command History
This guide is platform-specific. For command information about other platforms, see the relevant Dell Networking
OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
104 Control and Monitoring