Administrator Guide

stack port state to up: 3/1
Jul 30 16:34:23: %PE255-UNIT1-M:CP %CHMGR-5-STACKUNIT_UP: stack-unit 3 is up
Jul 30 16:34:23: %PE255-UNIT1-M:CP %CHMGR-5-CHECKIN: Checkin from stack-unit
3 (type C1048P, 52 ports)
Jul 30 16:34:20: %PE255-UNIT1-M:CP %CHMGR-5-STACKUNIT_DETECTED: stack-unit 3
present
Jul 30 16:34:11: %PE255-C1048P:1 %IFAGT-5-STACK_PORT_LINK_UP: Changed stack
port state to up: 1/2
Jul 30 16:34:11: %PE255-C1048P:2 %IFAGT-5-STACK_PORT_LINK_UP: Changed stack
port state to up: 2/1
Jul 30 16:34:07: %PE255-UNIT2-S:CP %EVL-6-EVENT_LOGGING: Completed uploading
pre-recorded traps(send count:1, pending traps:0) to CB
Jul 30 16:34:07: %PE255-UNIT2-S:CP %EVL-6-EVENT_LOGGING: Start uploading pre-
recorded traps(count:1) to CB
Jul 30 16:34:05: %PE-UNKN-UNIT2-S:CP %RAM-5-STACKUNIT_STATE: Stack-unit 2 is
in Standby State.
Jul 30 16:33:17: %PE255-UNIT1-M:CP %IRC-6-IRC_COMMUP: Link to peer Stack-
unit is up
Jul 30 16:33:10: %PE255-UNIT1-M:CP %BRM-5-BRM_INVALID_PE_LLDP_TIMEOUT: LLDP
PE TLV timeout received info on interface TenGigabitEthernet 1/1 not matches
existing info in DB!
Jul 30 16:33:07: %PE255-UNIT1-M:CP %POLLMGR-2-ALT_STACKUNIT_STATE: Alternate
Stack-unit is present
Jul 30 16:33:03: %PE255-UNIT1-M:CP %SEC-5-LOGIN_SUCCESS: Login successful on
console
Jul 30 16:33:03: %PE255-UNIT1-M:CP %SEC-3-AUTHENTICATION_FAILURE:
Authentication failure on console for method "local" user ""
Jul 30 16:33:03: %PE255-UNIT1-M:CP %RAM-5-STACKUNIT_STATE: Stack-unit 1 is
in Active State.
Jul 30 16:33:02: %PE255-UNIT1-M:CP %RAM-5-HOT_FAILOVER: Stack-unit Failover
Completed.
Jul 30 16:33:02: %PE255-UNIT1-M:CP %CHMGR-2-SYSTEM_READY: System ready
Jul 30 16:33:01: %PE255-UNIT1-M:CP %CHMGR-2-SWITCH_MANAGEMENT: stack-unit 2
successfully switched to new Management stack-unit
Jul 30 16:32:59: %PE255-UNIT1-M:CP %IFMGR-1-DEL_PORT: Removed port:
Jul 30 16:32:59: %PE255-UNIT1-M:CP %IFMGR-5-OSTATE_DN: Changed interface
state to down: Te 3/1
Jul 30 16:32:59: %PE255-UNIT1-M:CP %CHMGR-2-STACKUNIT_DOWN: stack-unit 3
down - card removed
Jul 30 16:32:59: %PE255-UNIT1-S:CP %POLLMGR-2-ALT_STACKUNIT_STATE: Alternate
Stack-unit is not present
Jul 30 16:32:58: %PE255-UNIT1-S:CP %RAM-6-ELECTION_ROLE: Stack-unit 1 is
transitioning to Management Stack-unit.
Jul 30 16:32:58: %PE255-UNIT1-S:CP %RAM-6-FAILOVER_REQ: Stack-unit failover
request from active peer: User request.
Jul 30 16:31:33: %PE255-UNIT3-M:CP %CHMGR-4-TEMP_STATUS_CHANGE: Unit 2
temperature state changed to 1 (Current temperature 36C).
Jul 30 16:31:33: %PE-UNKN-C1048P:2 %CHMGR-2-FAN_SPEED_CHANGE: Fan speed
changed to 75 % of the full speed
Jul 30 16:31:32: %PE255-UNIT3-M:CP %IFMGR-5-OSTATE_UP: Changed interface
state to up: Te 2/1
Jul 30 16:31:32: %PE-UNKN-C1048P:2 %CHMGR-2-FAN_SPEED_CHANGE: Fan speed
changed to 60 % of the full speed
Jul 30 16:31:32: %PE255-UNIT3-M:CP %CHMGR-5-FANTRAY_INSERTED: Fan tray 0 of
Unit 2 is inserted
Jul 30 16:31:32: %PE-UNKN-C1048P:2 %CHMGR-2-FAN_SPEED_CHANGE: Fan speed
changed to 60 % of the full speed
Jul 30 16:31:32: %PE255-UNIT3-M:CP %CHMGR-0-PS_DOWN: Major alarm: Power
supply 1 in unit 2 is down
Jul 30 16:31:32: %PE255-UNIT3-M:CP %CHMGR-5-PEM_INSERTED: Power entry module
1 of unit 2 is inserted
Jul 30 16:31:32: %PE255-UNIT3-M:CP %CHMGR-0-PS_UP: Power supply 0 in unit 2
is up
Jul 30 16:31:32: %PE255-UNIT3-M:CP %CHMGR-5-PEM_INSERTED: Power entry module
0 of unit 2 is inserted
Jul 30 16:31:25: %PE-UNKN-C1048P:2 %IFAGT-5-INSERT_OPTICS_PLUS: Optics SFP+
inserted in slot 2 port 1
Jul 30 16:31:25: %PE-UNKN-C1048P:2 %IFAGT-5-STACK_PORT_LINK_UP: Changed
stack port state to up: 2/2
Jul 30 16:31:25: %PE-UNKN-C1048P:2 %IFAGT-5-STACK_PORT_LINK_UP: Changed
stack port state to up: 2/1
Jul 30 16:31:24: %PE255-UNIT3-M:CP %CHMGR-5-STACKUNIT_UP: stack-unit 2 is up
Simple Network Management Protocol (SNMP) and Syslog
1519