Administrator Guide

Command History
This guide is platform-specific. For command information about other platforms, see the relevant Dell Networking
OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.9(0.0) Introduced on the C9010.
9.2(1.0) Introduced on the Z9500.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.3.7.0 Introduced on the S4810.
8.5.1.0 Added support for 4-port 40G line cards on ExaScale.
8.1.1.0 Introduced on the E-Series ExaScale.
7.8.1.0 Output augmented with diagnostic data for pluggable media.
7.7.1.0 Removed three fields in the output: Vendor Name, Vendor OUI, and Vendor PN.
7.6.1.0 Introduced on the C-Series and S-Series.
6.5.4.0 Introduced on the E-Series.
Usage Information The following describes the show interfaces transceiver command shown in the following example.
Line Description
Rx Power
measurement type
Output depends on the vendor, typically either “Average” or “OMA” (Receiver optical
modulation amplitude).
Temp High Alarm
threshold
Factory-defined setting, typically in Centigrade. Value differs between SFPs and SFP+.
Voltage High
Alarm threshold
Displays the interface index number that SNMP uses to identify the interface.
Bias High Alarm
threshold
Factory-defined setting. Value can differ between SFP and SFP+.
TX Power High
Alarm threshold
Factory-defined setting. Value can differ between SFP and SFP+.
RX Power High
Alarm threshold
Factory-defined setting. Value can differ between SFP and SFP+.
Temp Low Alarm
threshold
Factory-defined setting. Value can differ between SFP and SFP+.
Voltage Low Alarm
threshold
Factory-defined setting. Value can differ between SFP and SFP+.
Bias Low Alarm
threshold
Factory-defined setting. Value can differ between SFP and SFP+.
TX Power Low
Alarm threshold
Factory-defined setting. Value can differ between SFP and SFP+.
RX Power Low
Alarm threshold
Factory-defined setting. Value can differ between SFP and SFP+.
Temp High
Warning threshold
Factory-defined setting. Value can differ between SFP and SFP+.
Voltage High
Warning threshold
Factory-defined setting. Value can differ between SFP and SFP+.
Bias High Warning
threshold
Factory-defined setting. Value can differ between SFP and SFP+.
Interfaces 727