Administrator Guide

vlan
vlan-id
Enter the keywords vlan then the VLAN-id. The range is from 0 to 4094.
ether-type Enter the keywords ether-type in the XX:XX format.
Command Modes EXEC
Command History
This guide is platform-specific. For command information about other platforms, see the relevant Dell Networking
OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.9(0.0) Introduced on the C9010.
9.2(1.0) Introduced on the Z9500.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.3.10.0 Introduced on the S4810.
Usage Information
Because this command calculates based on a Layer 2 hash algorithm, use this command to display flows for
switched Layer 2 packets, not for routed packets (use the show ip flow command to display routed packets).
The show port-channel-flow command returns the egress port identification in a given port-channel if a
valid flow is entered. A mismatched flow error occurs if MAC-based hashing is configured for a Layer 2 interface
and you are trying to display a Layer 3 flow.
The output displays three entries:
Egress port for unfragmented packets.
In the event of fragmented packets, the egress port of the first fragment.
In the event of fragmented packets, the egress port of the subsequent fragments.
NOTE: In the show port channel flow command output, the egress port for an unknown
unicast, multicast, or broadcast traffic is not displayed.
The following example shows the show port-channel-flow outgoing-port-channel number
incoming-interface interface source-mac address destination-mac address
Load-balance is configured for MAC
Load-balance is configured for IP 4-tuple/2-tuple
A non-IP payload is going out of Layer 2 LAG interface that is a member of VLAN with an IP address
Example
Dell#show port-channel-flow port-channel 1 incoming-interface te 2/0
source-mac 00:00:50:00:00:00 destination-mac 00:00:a0:00:00:00
Egress Port for port-channel 1, for the given flow, is Te 2/1
Example: peGigE
Dell#show port-channel-flow port-channel 111 incoming-interface pegigE
111/0/33
src-mac 00:01:0b:00:00:00 dest-mac 00:01:0b:00:03:00 vlan 111 ether-type
ff:ff
Egress Port information for port-channel 111, for the given flow,is
PeGi 111/0/38.
HiGig Port Channel Commands
High-Gigabit Ethernet (HiGig) port channels are used to transmit data between internal backplane ports on line-card (leaf) and switch
fabric module (SFM - spine) network processing units (NPUs). You can configure an SNMP trap to be generated when traffic distribution
in a HiGig port channel is uneven.
NOTE: HiGig port channels on the backplane are also referred to as
HiGig link bundles
.
752 Interfaces