Specify the port extender ID and stack unit ID.
where pe-id is a port-extender group ID number from 0 to 255
stack-unitunit-number is a PE stack-unit number from 0 to 7
Dell#diag pe 0 stack-unit 0
A warning is displayed with a CLI prompt asking you to click Yes or No.
Dell#diag pe 0 stack-unit 0 level0 ?
Warning - PE-Unit 0 at PEID 0 will go offline to run the diagnostics.
Offline of system will bring down all the protocols and the system
will be operationally down, except for running Diagnostics.
PE unit will be automatically reloaded once the diagnostics tests are
completed.
Warning - The diagnostic execution will cause multiple link flaps on
the peer side
- advisable to shut directly connected ports
Proceed with PE diag [confirm yes/no]:yes
After completing the diagnostics on the PE, the PE reboots automatically reboots and then the switch and PE connection is
established. The switch copies the diagnostic report le into the PE master ash.
2 Upload the diagnostics report le into the switch.
EXEC Privilege mode
show diag pe pe-id stack-unit unit-number
This command copies the diagnostics report from the PE to the switch’s ash. The name of the le that is copied is printed as part of
the CLI output.
For example:
Dell#show diag pe 0 stack-unit 0
% Diag Report fileflash:/DEFAULT_DIAG_REPORT_DIR/TestReport-SU-0-PE-0-20150312_045748.txt
copied successfully.
3 View the results of the diagnostics test from the console.
EXEC Privilege Mode
show le file-name
The le-name refers to the le name that is displayed in the show diag pe command.
In this case, TestReport-SU-0-PE-0-20150312_045748.txt
show file flash://DEFAULT_DIAG_REPORT_DIR/TestReport-SU-0-PE-0-20150312_045748.txt
Diagnostic results are stored to a le in the ash using the lename format:
ash://DEFAULT_DIAG_REPORT_DIR/TestReport-SU-<stack-unit>-PE-<PEID>.txt
Dell#00:20:26 : Diagnostic test results are stored on flash://DEFAULT_DIAG_REPORT_DIR/
TestReport-SU-0-PE-020150312_045748.txt
Examples of Running Oine Diagnostics on the Port Extender
The following example shows how to verify the oine/online status of the PE.
Dell#diag pe 255 stack-unit 2 alllevels
Warning - PE-Unit 2 at PEID 255 will go offline to run the diagnostics.
Taking Port Extender unit offline for running diagnostics
will make it operationally down, causing traffic disruption through the unit.
If stacking is configured, the unit roles may change. This unit 2 will become standalone once
diags are executed.