-- Unit Environment Status --
Unit Status Temp Voltage
----------------------------------
* 1 online 28C ok
* Management Unit
-- Thermal Sensor Readings (deg C) --
Unit Sensor-CPU Sensor-MAC Sensor-Left Sensor-Right Sensor-QSFP Sensor-DCFAN Sensor-BCM
----------------------------------------------------------------------------------------------
1 25 28 25 22 26 23 36
Example (System
Power Log)
This output is applicable for the C1048P, N20xx, and N30xx series port-extenders.
DellEMC# show env
-- Fan Status --
Unit Bay TrayStatus Fan1 Speed Fan2 Speed
-------------------------------------------------------
1 1 up up 9056 up 9056
1 2 up up 9037 up 9037
Speed in RPM
-- Power Supplies --
Unit Bay Status Type FanStatus FanSpeed(rpm)
--------------------------------------------------------
1 1 up AC up NA
1 2 up AC up NA
Unit TotalPower AvgPower AvgPowerStartTime
------------------------------------------------
1 30 26 05/25/2017-19:18
show inventory
Display the switch type, components (including media), and Dell Networking OS version, including hardware identification numbers and
configured protocols.
C9000 Series
Syntax
show inventory [media [slot-id | pe pe-id [stack-unit unit-number]]| pe pe-id]]
From a PE console, use show inventory [media] to view the PE inventory information.
Parameters
media
slot-id
(OPTIONAL) Enter the keyword media to display pluggable media inventory for a
specified line-card slot. Valid slot IDs are from 0 to 2.
pe
pe-id
(OPTIONAL) Enter the keyword pe to display port extender (PE) inventory for a
specified PE ID. Range is from 0 to 255.
NOTE: The pe option is only available when the extended bridge feature is
enabled.
Defaults none
Command Modes CONFIGURATION
Command History
This guide is platform-specific. For command information about other platforms, see the relevant Dell Networking
OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.9 (0.0) Introduced on the C9010 and C1048P.
Control and Monitoring 107