Administrator Guide

interface
interface
(OPTIONAL) Enter the keyword interface and specify the interface type and slot/
port numbers or port-channel number to display the PVLAN configuration for a member
interface. The valid values are:
For a port channel interface, enter the keyword port-channel and a port-channel
ID.
For a 10-Gigabit Ethernet interface, enter the keyword tenGigabitEthernet then
the slot/port information.
For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/
port information.
For a port extender (PE) Gigabit Ethernet interface, enter the keyword peGigE then
the pe-id / stack-unit / port-id information.
For a port extender 10-Gigabit Ethernet interface, enter the keyword peTenGigE
then the pe-id / stack-unit / port-id information. The pe-id range is from 0 to 255;
the stack-unit
unit-number range is from 0 to 7; and the port-id range is 25 to 28 or
49 to 52 depending on the PE.
isolated (OPTIONAL) Enter the keyword isolated and a PVLAN ID number to display the
configuration of an isolated PVLAN.
mapping (OPTIONAL) Enter the keyword mapping to display the community and isolated PVLAN
mapping to primary PVLANs.
primary
vlan-id
(OPTIONAL) Enter the keyword primary and a PVLAN ID number to display the
configuration of a primary PVLAN.
Defaults none
Command Modes
EXEC
EXEC Privilege
Command History
This guide is platform-specific. For command information about other platforms, see the relevant Dell Networking
OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.13.0.1P1 Introduced peTenGigE interface support on the C9010.
9.9(0.0) Introduced on the C9010.
9.2(1.0) Introduced on the Z9500.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.3.7.1 Introduced on the S4810.
7.8.1.0 Introduced on the C-Series and S-Series.
Usage Information
Examples of all types of command output are shown below. The first type of output is the result of not entering
an optional keyword. It displays a detailed list of all PVLANs and their member VLANs and interfaces. The other
types of output show details about PVLAN subsets.
The following describes the show private-vlan command shown in the Examples below.
Field Description
Primary Displays the VLAN ID of the designated or associated primary VLAN(s).
Secondary Displays the VLAN ID of the designated or associated secondary VLAN(s).
Type Displays the type of VLAN in which the listed interfaces reside.
Active States whether the interface is operationally up or down.
Ports Displays the interface IDs in the listed VLAN.
1346 Private VLAN (PVLAN)