Administrator Guide

NOTE: The flow control feature is not supported on the Port Extender Gigabit Ethernet (peGigE)
interface.
Example
Dell(conf-if-te-0/1)# show config
!
interface TengigabitEthernet 0/1
no ip address
switchport
no negotiation auto
flowcontrol rx off tx on monitor 9
no shutdown
...
Related
Commands
show running-config — displays the flow configuration parameters (non-default values only).
show interfaces — displays the negotiated flow control parameters.
interface
Configure a physical or logical interfaces on the switch.
C9000 Series
Syntax
interface interface range [group interface]
Parameters
interface
Enter one of the following keywords and slot/port, pe-id /stack-unit or number
information:
For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/
port information.
For a Gigabit Ethernet interface, enter the keyword GigabitEthernet then the
slot/port information.
For a Loopback interface, enter the keyword loopback then the slot/port
information. The range is from 0 to 16383.
For a Management Ethernet interface, enter the keyword managementethernet
then the slot/port information.
For a null interface, enter the keyword null then the slot/port information. The Null
interface number is 0.
For a Port Channel interface, enter the keyword port-channel then the port-
channel ID. Range is from 1 to 4096.
For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then
the slot/port information.
For a Tunnel interface, enter the keyword tunnel then the tunnel ID. The range is
from 1 to 16383.
For a VLAN interface, enter the keyword vlan then the slot/port information. The
range is from 1 to 4094.
For a port extender Gigabit Ethernet interface, enter the keyword peGigE then the
pe-id / stack-unit / port-id information. The pe-id range is from 0 to 255; the stack-
unit unit-number range is from 0 to 7; and the port-id range is from 1 to 48.
For a port extender 10-Gigabit Ethernet interface, enter the keyword peTenGigE
then the pe-id / stack-unit / port-id information. The pe-id range is from 0 to 255;
the stack-unit
unit-number range is from 0 to 7; and the port-id range is 25 to 28 or
49 to 52 depending on the PE.
group
interface
(Optional) Enter the keyword group to configure an interface group. You can create a
interface group by adding a comma or hyphen separate list of the following interface
types:
fortyGigE for a 40–Gigabit Ethernet interface.
gigabitethernet for a GigabitEthernet interface.
690 Interfaces