Administrator Guide

Line Description
Voltage High
Alarm threshold
Displays the interface index number that SNMP uses to identify the interface.
Bias High Alarm
threshold
Factory-defined setting. Value can differ between SFP and SFP+.
TX Power High
Alarm threshold
Factory-defined setting. Value can differ between SFP and SFP+.
RX Power High
Alarm threshold
Factory-defined setting. Value can differ between SFP and SFP+.
Temp Low Alarm
threshold
Factory-defined setting. Value can differ between SFP and SFP+.
Voltage Low Alarm
threshold
Factory-defined setting. Value can differ between SFP and SFP+.
Bias Low Alarm
threshold
Factory-defined setting. Value can differ between SFP and SFP+.
TX Power Low
Alarm threshold
Factory-defined setting. Value can differ between SFP and SFP+.
RX Power Low
Alarm threshold
Factory-defined setting. Value can differ between SFP and SFP+.
Temp High
Warning threshold
Factory-defined setting. Value can differ between SFP and SFP+.
Voltage High
Warning threshold
Factory-defined setting. Value can differ between SFP and SFP+.
Bias High Warning
threshold
Factory-defined setting. Value can differ between SFP and SFP+.
TX Power High
Warning threshold
Factory-defined setting. Value can differ between SFP and SFP+.
RX Power High
Warning threshold
Factory-defined setting. Value can differ between SFP and SFP+.
Temp Low
Warning threshold
Factory-defined setting. Value can differ between SFP and SFP+.
Voltage Low
Warning threshold
Factory-defined setting. Value can differ between SFP and SFP+.
Bias Low Warning
threshold
Factory-defined setting. Value can differ between SFP and SFP+.
TX Power Low
Warning threshold
Factory-defined setting. Value can differ between SFP and SFP+.
Power Low
Warning threshold
Factory-defined setting. Value can differ between SFP and SFP+.
Temperature Current temperature of the SFPs. If this temperature crosses Temp High alarm/warning
thresholds, the temperature high alarm/warning flag is set to true.
Voltage Current voltage of the SFPs. If this voltage crosses voltage high alarm/warning
thresholds, the voltage high alarm/warning flag is set to true.
Tx Bias Current Present transmission (Tx) bias current of the SFP. If this crosses bias high alarm/warning
thresholds, the TX bias high alarm/warning flag is set to true. If it falls below the low
alarm/warning thresholds, the TX bias low alarm/warning flag is set to true.
Tx Power Present Tx power of the SFP. If this crosses Tx power alarm/warning thresholds, the Tx
power high alarm/warning flag is set to true. If it falls below the low alarm/warning
thresholds, the Tx power low alarm/ warning flag is set to true.
742 Interfaces