Users Guide

threshold. If unevenness is recorded for three consecutive measurements, an alarm event is generated. The rate interval denes the
time interval between measurements.
Enabling HiGig Link-Bundle Monitoring
To enable the monitoring of HiGig link bundles, follow these steps.
1 Enable the monitoring of trac distribution on the member links in a HiGig link bundle (port-channel).
CONFIGURATION mode
Dell(conf)#hg-link-bundle-monitor {sfm npu-id hg-port—channel hg-port—channel-id | slot slot
npuUnit npu-id hg-port—channel 0} enable
2 Specify the trigger threshold for HiGig link-bundle monitoring.
CONFIGURATION mode
Dell(conf)#hg-link-bundle-monitor trigger-threshold percentage
3 Specify the interval (in seconds) when HiGig link-bundle monitoring is performed.
CONFIGURATION mode
Dell(conf)#hg-link-bundle-monitor rate-interval seconds
4 Enable SNMP trap generation for HiGig link-bundle monitoring.
CONFIGURATION mode
Dell(conf)#snmp-server enable traps hg-lbm
5 Display the trac utilization of member links in a HiGig link bundle (port channel).
EXEC, EXEC Privilege modes
Dell#show hg-link-bundle-distribution {sfm npu-id hg-port—channel hg-port—channel-id | slot
slot npuUnit npu-id hg-port—channel 0}
Non Dell-Qualied Transceivers
The system supports Dell-qualied transceivers and only some of the non Dell-qualied transceivers.
The system supports the following cables and adapters:
DAC cables
AOC cables
AOC fan-out cables
DAC fan-out cables
40G ber breakout cables
10G AOC and DAC cables
1G optics
QSA
If you use any of the cables or adapters in the preceding list that is not Dell-qualied, the Dell Networking OS detects it and makes it
operational. The system displays a syslog message similar to the following:
Apr 29 05:09:16: %S4048-ON:1 %IFAGT-5-UNSUP_OPTICS: Non-qualified optics in slot 1 port 49
The system supports the following types of transceivers only if they are Dell-qualied:
LR4
Interfaces
467