Users Guide

Reason: CTM - Card Type Mismatch, CAM - CAM ACL Mismatch
SVM - Software Version Mismatch, UE - Unknown Error
Offline Reason: UNP - Unit Not Present, PVE - Port Validation Error
ICE - IPC CP Error, IRE - IPC RP Error
ISE - IPC Setup Error, CVE - Card Validation Error
PE-ID assigned: 1
Status: online
System Mac: f8:b1:56:73:a2:91
PE Up Time: 03:00:27
PE Description:
PE Discovery Status: Provisioned PE
User Configured Cascade Ports: Te 0/16(A)
Cascade LAG: Po 259, Local Status: Up, Remote Status: Down
PE Configuration: Local Status: Present, Remote Status: Not Present
---------------------------------------------------------------------------------------------
Stack-id Status Reason Type UnitMac No. of Ports Description
---------------------------------------------------------------------------------------------
0 online - N2048P-PE f8:b1:56:73:a2:91 52
1 online - N2048P-PE f8:b1:56:73:a2:89 52
2 online - N3024P-PE f4:8e:38:02:b1:43 30
NOTE: In the User-Congured Cascade Ports eld, A (active) indicates that a C9010 port is up (no shutdown) and congured
as a cascade port; I (inactive) indicates that a port is down and congured as a cascade port.
Dell# show interface port-channel brief
Codes: L - LACP Port-channel
O - OpenFlow Controller Port-channel
A - Auto Port-channel
LAG Mode Status Uptime Ports
A 258 N/A up 14:45:26 Te 0/1,2 (up)
Port Extender Limit
You can connect a maximum of 80 PE units to the C9010 control bridge.
Dell EMC Networking OS enforces a hard-limit of a maximum of 4000 PEX ports to be congured on each CB. This port limit on each CB
applies to both PEX ports as well as uplink ports that are converted to access (PEX) ports.
The PEX port count could increment in the following scenarios:
Provisioning of PE units in the local mode, where all the supported PEX ports on each PE are provisioned.
Converting uplink ports to access (PEX) ports.
Remote provisioning of PEs in a VLT dual homing setup. Dell EMC Networking OS recommends to perform PE provisioning for VLT only
in the batch mode.
Converting uplink ports to access (PEX) ports in a VLT dual homing setup. Dell EMC Networking OS recommends to perform the uplink
port conversion in VLT dual homing setups only using the batch mode.
If the number of PEX ports that you are trying to provision exceeds the prescribed hard-limit (4000), the system logs the following syslog
message:
Maximum number of PE ports limit (4000) reached. Rejected PE:PE Id Unit:PE Unit Id
configuration!.
The system also stops the provisioning of the extra ports or conversion of the uplink ports that is causing the PEX port limit to exceed the
hard-limit.
Port Extenders (PEs)
749