Administrator Guide

Service Tag : CL73Z01
Expr Svc Code : 274 031 203 69
Auto Reboot : enabled
Burned In MAC : f8:b1:56:00:02:d1
No Of MACs : 66
-- Power Supplies --
Unit Bay Status Type FanStatus FanSpeed(rpm)
-------------------------------------------------------------
2 0 up AC NA NA
2 1 up DC NA NA
-- Fan Status --
Unit Bay TrayStatus Fan0 Speed Fan1 Speed
------------------------------------------------------------
2 0 up up 9056 up 9056
Speed in RPM
Display the type of stack topology (ring or daisy chain) with a list of all stack ports, port status, and link speed. The interface values are
in the format pe-id/stack-port. Enter the PE ID of the master unit.
show pe pe-id system stack-ports status
Dell#show pe 255 system stack-ports status
Topology: Ring
Interface Link Speed Admin Link
(Gb/s) Status Status
--------------------------------------------
1/1 24 up up
1/2 24 up up
2/1 24 up up
2/2 24 up up
3/1 24 up up
3/2 24 up up
Display the type of stack topology (ring or daisy chain) and the stack-port connections on peer stack-units in the ring. The interface
and connection values are in the format pe-id/stack-port. Enter the PE ID of the master unit.
show pe pe-id system stack-ports topology
Dell#show pe 255 system stack-ports topology
Topology: Ring
Interface Connection
---------------------
1/1 3/1
1/2 2/1
2/1 1/2
2/2 3/2
3/1 1/1
3/2 2/2
Configuring the Unused PE Uplink Ports as Front-
End Ports
In a stacked PE setup, you can configure an unused uplink port as front-end (access) ports.
If there are unused uplink ports in the stacked PE setup, it can be converted as access port. This configuration is done using the following
command:
stack-unit unit-id access—ports port-range
CAUTION:
You should use caution while configuring an uplink port as access port. The conversion of the uplink port that is
connected to CB causes disconnection of PE. If disconnected, you have to convert the access port back to uplink port
using no stack-unit unit-number access-ports port-range command and reload the PE.
Port Extender (PE) Stacking 699