Administrator Guide

Version Description
7.4.1.0 Introduced on the E-Series.
Usage Information The monitoring command is saved in the running configuration at the Monitor Session mode level and can be
restored after a chassis reload.
Example
Dell(conf-mon-sess-0)#do show running-config monitor session
!
monitor session 0
source Port-channel 10 destination TenGigabitEthernet 0/33 direction tx
!
Related
Commands
monitor session — creates a monitoring session.
show monitor session — displays a monitoring session.
source (port monitoring)
Configure a port monitor source.
C9000 Series
Syntax
source interface | range destination interface direction {rx | tx | both}
To disable a monitor source, use the no source interface destination interface direction
{rx | tx | both} command.
Parameters
source
interface
Enter the one of the following keywords and slot/port information:
For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then
the slot/port information.
For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/
port information.
For a port channel interface, enter the keyword port-channel and a port-channel
ID.
For a port extender (PE) Gigabit Ethernet interface, enter the keyword peGigE then
the pe-id / stack-unit / port-id information.
For a port extender 10-Gigabit Ethernet interface, enter the keyword peTenGigE
then the pe-id / stack-unit / port-id information. The pe-id range is from 0 to 255;
the stack-unit unit-number range is from 0 to 7; and the port-id range is 25 to 28 or
49 to 52 depending on the PE.
For a VLAN interface, enter the keyword VLAN and a vlan-id number. Range is from 1
to 4094.
For a remote VLAN interface, enter the keyword Remote-VLAN and a vlan-id
number. Range is from 1 to 4094
For a port channel interface, enter the keyword port-channel and a port-channel
ID.
NOTE: You cannot configure VLAN 4092 and 4093. These VLANs are
reserved for internal use.
range Enter the keyword range to specify the list of interfaces.
destination Enter the keyword destination to specify the destination interface.
For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then
the slot/port information.
For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/
port information.
Port Monitoring 1339