Administrator Guide

channel-member
Add an interface to the Port Channel, while in INTERFACE PORTCHANNEL mode.
C9000 Series
Syntax
channel-member interface
To delete an interface from a Port Channel, use the no channel-member interface command.
Parameters
interface
(OPTIONAL) Enter any of the following keywords and slot/port, peid/stack-unit/port-id,
or number information:
For a Gigabit Ethernet interface, enter the keyword GigabitEthernet then the
slot/port information.
For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then
the slot/port information.
For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/
port information.
For a port extender Gigabit Ethernet interface, enter the keyword peGigE then the
pe-id / stack-unit / port-id information. The pe-id range is from 0 to 255; the stack-
unit unit-number range is from 0 to 7; and the port-id range is from 1 to 48.
For a port extender 10-Gigabit Ethernet interface, enter the keyword peTenGigE
then the pe-id / stack-unit / port-id information. The pe-id range is from 0 to 255;
the stack-unit unit-number range is from 0 to 7; and the port-id range is 25 to 28 or
49 to 52 depending on the PE.
Defaults Not configured.
Command Modes INTERFACE PORTCHANNEL
Command History
This guide is platform-specific. For command information about other platforms, see the relevant Dell Networking
OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.13.0.1P1 Introduced peTenGigE interface support on the C9010.
9.9(0.0) Introduced on the C9010.
9.2(1.0) Introduced on the Z9500.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.5.1.0 Added support for 4-port 40G line cards on ExaScale.
8.3.7.0 Introduced on the S4810.
8.1.1.0 Introduced on the E-Series ExaScale.
7.6.1.0 Introduced on the S-Series.
7.5.1.0 Introduced on the C-Series.
6.2.1.0 Introduced on the E-Series.
Usage Information
Use the interface port-channel command to access this command.
You cannot add an interface to a Port Channel if the interface contains an IP address in its configuration. Only the
shutdown, description, mtu, and ip mtu commands can be configured on an interface if it is added to a
Port Channel. The
mtu and ip mtu commands are only available when the chassis is in Jumbo mode.
Link MTU and IP MTU considerations for Port Channels are:
All members must have the same link MTU value and the same IP MTU value.
758 Interfaces