Reference Guide

From a PE console, use reload to perform a cold restart.
Parameters
conditional
nvram-cfg-
change
Reload if the condition is true. A configuration change to
the nvram requires a switch reload. To reload the switch,
select nvram-cfg-change.
pe Reload the RMP, PE unit, or the entire PE stack configured
under that PE unit.
Command Modes EXEC Privilege
Command History
This guide is platform-specific. For command information about other platforms,
see the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.9(0.0) Introduced on the C9010 and C1048P.
9.2(1.0) Introduced on the Z9500.
9.1(0.0) Added ‘conditional’ parameter.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
7.6.1.0 Introduced on the S-Series.
7.5.1.0 Introduced on the C-Series.
E-Series Original command.
Usage Information If there is a change in the configuration, the system prompts you to save the new
configuration. Or you can save your running configuration with the copy
running-config command. Use the conditional parameter if any configuration
changes made to the nvram, such as stack-group and fanout configurations, must
be saved.
To halt a port extender (PE) or an entire PE stack, and perform a cold-restart (from
a PE console), use the reload command.
send
Send messages to one or all terminal line users.
C9000 Series
Syntax
send [*] | [line ] | [console] | [vty]
Control and Monitoring
103