Reference Guide

To disable sFlow, use the no sflow enable command.
Defaults Disabled.
Command Modes INTERFACE
Command History
This guide is platform-specific. For command information about other platforms,
refer to the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.9(0.0) Introduced on the C9010.
9.2(1.0) Introduced on the Z9500.
8.3.19.0 Introduced on the S4820T.
8.3.16.1 Introduced on the MXL 10/40GbE Switch IO Module.
8.3.11.1 Introduced on the Z9000.
8.3.7.0 Introduced on the S4810.
8.2.1.0 Introduced on S-Series Stacking.
8.1.1.0 Introduced on the E-Series ExaScale.
7.7.1.0 Introduced on the S-Series.
7.6.1.0 Introduced on the C-Series.
6.2.1.1 Introduced on the E-Series.
Usage Information When you enable sFlow on an interface, flow sampling is done on any traffic going
out of the interface.
NOTE: After a physical port is a member of a LAG, it inherits the sFlow
configuration from the LAG port.
sflow ingress-enable
Enable sFlow ingress on interfaces.
C9000 Series
Syntax
sflow ingress-enable
To disable sFlow, use the no sflow ingress enable command.
Defaults Disabled.
Command Modes INTERFACE
1898
sFlow