Reference Guide

You may specify both bytes of the 2-byte S-Tag TPID. The
range is from 0 to FFFF. The default is 9100.
Defaults 0x9100
Command Modes CONFIGURATION
Command History
This guide is platform-specific. For command information about other platforms,
see the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.9(0.0) Introduced on the C9010.
9.2(1.0) Introduced on the Z9500.
8.3.19.0 Introduced on the S4820T.
8.3.7.0 Introduced on the S4810.
8.2.1.0 Introduced on the E-Series ExaScale. C-Series and S-Series
accept both bytes of the 2-byte S-Tag TPID.
8.2.1.0 Introduced on the E-Series ExaScale.
7.6.1.0 Introduced on the C-Series and S-Series.
Usage Information
For specific interoperability limitations regarding the S-Tag TPID, see the Dell
Networking OS Configuration Guide.
The four characters you enter in the CLI for number are interpreted, as shown in
the following table.
Number Resulting TPID
1 0x0001
10 0x0010
81 0x0081
8100 0x8100
Related
Commands
portmode hybrid — sets a port (physical ports only) to accept both tagged and
untagged frames. A port configured this way is identified as a hybrid port in
report displays.
vlan-stack trunk — specifies a Layer 2 port or port channel as a trunk port to the
Stackable VLAN network.
2116
VLAN Stacking