Reference Guide

terminate Enter the keyword terminate to stop the offline diagnostic
tests that are running.
Defaults All offline diagnostic tests are run on all switch CPUs (Control Processor, Route
Processor, and line cards).
Command Modes EXEC Privilege
Usage Information
Before you use this command to run diagnostic test, make sure that the switch is
offline (offline system command).
You are prompted to reboot when the offline diagnostics complete.
The PE unit goes offline and reboots automatically after the test is completed.
Use the show diag command to view a summary of diagnostic information
presented for each switch CPU. For PE, this command is used to upload the
TestReport from the PE to the C9000 in the DEFAULT_DIAG_REPORT_DIR. For
example:
Dell#pwd flash:/DEFAult_diag_report_dir
Use the show diag command to upload the diag TestReport as
shown below:
Dell#show diag pe 8 stack-unit 0
% Diag Report file flash:/DEFAULT_DIAG_REPORT_DIR/TestReport-
SU-0-PE-8-20150328_200647.txt copied successfully.
Dell#dir Directory of flash:/DEFAult_diag_report_dir
1 drwx 4096 Mar 12 2015 22:53:32 +00:00 .
2 drwx 4096 Jan 01 1980 00:00:00 +00:00 ..
3 -rwx 8971 Mar 28 2015 20:06:52 +00:00 TestReport-
SU-0-PE-8-20150328_200647.txt
flash: 4490649600 bytes total (3658694656 bytes free)
At the end of offline diagnostic tests, a test report is generated. The filename of the
report is TestReport-{CP/LP/RP}-N.txt, where {CP/LP/RP}-N identifies the CPU and
CPU ID on which the diagnostics were run: Route Processor 0, Control Processor
0, and a line-card CPU {0–2}. The report is stored at flash:// and ramdisk:/
diagnostic. Offline diag test reports for port extender (PE) are stored in the
following directory: flash:/default_diag_report_dir. To view the test
report, use the
show file flash://filename command. A sample filename is
TestReport-LP-2.
Command History
This guide is platform-specific. For command information about other platforms,
see the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.9(0.0) Introduced on the C9010 and C1048P.
9.2(1.0) Introduced on the Z9500.
698
Debugging and Diagnostics