Reference Guide

offline system
Place the switch in the offline state in order to run diagnostic tests.
C9000 Series
Syntax
offline system
Defaults none
Command Modes EXEC Privilege
Command History
This guide is platform-specific. For command information about other platforms,
see the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.9(0.0) Introduced on the C9010.
9.2(1.0) Introduced on the Z9500.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.3.7.0 Introduced on the S4810.
8.2.1.0 Added a warning message to the off-line diagnostic.
7.7.1.0 Introduced on the S-Series.
Usage Information
To run diagnostic tests on an offline switch, use the diag command.
The system reboots when offline diagnostics complete. This reboot is an automatic
process. A warning message appears when the offline system command is
implemented.
Warning - Diagnostic execution will cause system to reboot
after completion of diags.
Proceed with Offline-Diags [confirm yes/no]:y
Related
Commands
diag — run diagnostic tests on an offline switch.
700
Debugging and Diagnostics