Reference Guide

pe pe-id Enter the keyword pe and the port extender ID to force the
standby stack unit to become the primary (or master) stack
unit. Range is from 0 to 255.
Default Not configured.
Command Modes EXEC Privilege
Command History
This guide is platform-specific. For command information about other platforms,
see the relevant Dell Networking OS Command-Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.9(0.0) Introduced on the C9010.
9.2(0.0) Introduced on the M I/O Aggregator. This command is
supported in Programmable-Mux (PMUX) mode only.
8.3.19.0 Introduced on the S4820T.
8.3.12.0 Introduced on the S4810.
8.1.1.0 Introduced on the E-Series ExaScale.
7.5.1.0 Introduced on the C-Series.
7.6.1.0 Introduced on the E-Series.
Usage Information
The redundancy force-failover pe command forces a standby port extender
unit to become a primary (or master) unit.
Example
Dell#redundancy force-failover pe 255
Related
Commands
stack-unit — Pre-provision the specified port-extender stack unit.
redundancy primary
Set an RPM as the primary RPM.
C9000 Series
Syntax
redundancy primary [rpm0 | rpm1]
To delete a configuration, use the no redundancy primary command.
Parameters
rpm0 Enter the keyword rpm0 to set the RPM in slot R0 as the
primary RPM.
854