Setup Guide

PE unit will be automatically reloaded once the diagnostics tests are completed.
Warning - The diagnostic execution will cause multiple link flaps on the peer side - advisable
to shut directly connected ports
Proceed with PE diag [confirm yes/no]:yes
Dell#
Jul 30 12:59:39: %RPM0-P:CP %BRM-5-PE_UNIT_DOWN: PE:255 Unit:2 Unit MAC:f8:b1:56:00:02:d1 is
operationally down.
Jul 30 12:59:44: %RPM0-P:CP %IFMGR-5-OSTATE_DN: Changed interface state to down: Te 6/0
Jul 30 12:59:37: %PE255-UNIT3-M:CP %CHMGR-2-STACKUNIT_DOWN: stack-unit 2 down - stack-unit
offline
Jul 30 12:59:37: %PE255-UNIT3-M:CP %IFMGR-5-OSTATE_DN: Changed interface state to down: Te 2/1
Jul 30 12:59:38: %PE255-UNIT3-M:CP %IFMGR-1-DEL_PORT: Removed port:
Jul 30 12:59:38: %PE255-UNIT1-S:CP %IFMGR-1-DEL_PORT: Removed port:
!!!!!
Jul 30 13:11:06: %PE255-UNIT3-M:CP %CHMGR-0-PS_UP: Power supply 0 in unit 2 is up
Jul 30 13:11:07: %PE255-UNIT3-M:CP %CHMGR-0-PS_DOWN: Major alarm: Power supply 1 in unit 2 is
down
Jul 30 13:11:07: %PE255-C1048P:2 %CHMGR-2-FAN_SPEED_CHANGE: Fan speed changed to 60 % of the
full speed
Jul 30 13:11:07: %PE255-UNIT3-M:CP %IFMGR-5-OSTATE_UP: Changed interface state to up: Te 2/1
Jul 30 13:11:54: %PE255-C1048P:2 %CHMGR-2-FAN_SPEED_CHANGE: Fan speed changed to 75 % of the
full speed
Jul 30 13:11:54: %PE255-UNIT3-M:CP %CHMGR-4-TEMP_STATUS_CHANGE: Unit 2 temperature state
changed to 1 (Current temperature 35C).
The following example shows how to upload diagnostics report from PE to the switch.
Dell# show diag pe 255 stack-unit 2
% Diag Report file flash:/DEFAULT_DIAG_REPORT_DIR/TestReport-SU-2-PE-255-20150730_131431.txt
copied successfully.
Dell#$DEFAULT_DIAG_REPORT_DIR/TestReport-SU-2-PE-255-20150730_131431.txt
Number of Bcm devices: 1
Dell#dir
Directory of flash:/default_diag_report_dir
1 drwx 16384 Mar 25 2015 14:26:10 +00:00 .
2 drwx 8192 Jan 01 1980 00:00:00 +00:00 ..
3 -rwx 97377 Jul 30 2015 07:52:04 +00:00 TestReport-SU-0-PE-10-20150730_075149.txt
The following example shows retrieving the diagnostics report for PE
Dell#show file TestReport-SU-2-PE-255-20150730_131431.txt
Number of Bcm devices: 1
DELL DIAGNOSTICS-C1048P-PEID(-1)-STACK ID(2) [0]
PPID -- NA
PPID Rev -- NA
Service Tag -- NA
Part Number -- NA
Part Number Revision -- NA
SW Version -- 1-0(0-4237)
NetBsd Version -- 1-0(0-4237)
Available free memory: 694,554,624 bytes
LEVEL 0 DIAGNOSTIC
308
Debugging and Diagnostics