White Papers

02:36:43: %SYSTEM-P:CP %IFMGR-5-OSTATE_DN: Downstream interface set to UFD error-disabled: Fo
1/4
02:36:43: %SYSTEM-P:CP %IFMGR-5-OSTATE_DN: Downstream interface set to UFD error-disabled: Fo
1/8
02:36:43: %SYSTEM-P:CP %IFMGR-5-OSTATE_DN: Downstream interface set to UFD error-disabled: Fo
1/12
02:36:43: %SYSTEM-P:CP %IFMGR-5-OSTATE_DN: Changed interface state to down: Fo 1/0
02:36:43: %SYSTEM-P:CP %IFMGR-5-OSTATE_DN: Changed interface state to down: Fo 1/4
02:36:43: %SYSTEM-P:CP %IFMGR-5-OSTATE_DN: Changed interface state to down: Fo 1/8
02:36:43: %SYSTEM-P:CP %IFMGR-5-OSTATE_DN: Changed interface state to down: Fo 1/12
02:37:29: %SYSTEM-P:CP %IFMGR-5-ASTATE_DN: Changed interface Admin state to down: Te 0/47
02:37:29: %SYSTEM-P:CP %IFMGR-5-OSTATE_DN: Changed interface state to down: Te 0/47
02:37:29 :
UFD: Group:3, UplinkState: DOWN
02:37:29: %SYSTEM-P:CP %IFMGR-5-OSTATE_DN: Changed uplink state group state to down: Group 3
02:37:29: %SYSTEM-P:CP %IFMGR-5-OSTATE_DN: Downstream interface set to UFD error-disabled: Fo
1/0
02:37:29: %SYSTEM-P:CP %IFMGR-5-OSTATE_DN: Changed interface state to down: Fo 1/0
02:38:31 : UFD: Group:3, UplinkState: UP
02:38:31: %SYSTEM-P:CP %IFMGR-5-OSTATE_UP: Changed uplink state group state to up: Group 3
02:38:53: %SYSTEM-P:CP %IFMGR-5-OSTATE_UP: Downstream interface cleared from UFD error-
disabled: Fo 1/0
02:38:53: %SYSTEM-P:CP %IFMGR-5-OSTATE_UP: Downstream interface cleared from UFD error-
disabled: Fo 1/4
02:38:53: %SYSTEM-P:CP %IFMGR-5-OSTATE_UP: Downstream interface cleared from UFD error-
disabled: Fo 1/8
02:38:53: %SYSTEM-P:CP %IFMGR-5-OSTATE_UP: Downstream interface cleared from UFD error-
disabled: Fo 1/12
02:38:53: %SYSTEM-P:CP %IFMGR-5-OSTATE_UP: Downstream interface cleared from UFD error-
disabled: Fo 1/16
02:38:53: %SYSTEM-P:CP %IFMGR-5-OSTATE_UP: Changed interface state to up: Fo 1/0
02:38:53: %SYSTEM-P:CP %IFMGR-5-OSTATE_UP: Changed interface state to up: Fo 1/4
02:38:53: %SYSTEM-P:CP %IFMGR-5-OSTATE_UP: Changed interface state to up: Fo 1/8
02:38:53: %SYSTEM-P:CP %IFMGR-5-OSTATE_UP: Changed interface state to up: Fo 1/12
02:38:53: %SYSTEM-P:CP %IFMGR-5-OSTATE_UP: Changed interface state to up: Fo 1/16
Displaying Uplink Failure Detection
To display information on the UFD feature, use any of the following commands.
Display status information on a specied uplink-state group or all groups.
EXEC mode
show uplink-state-group [group-id] [detail]
group-id: The values are 1 to 16.
detail: displays additional status information on the upstream and downstream interfaces in each group.
Display the current status of a port or port-channel interface assigned to an uplink-state group.
EXEC mode
show interfaces interface
interface species one of the following interface types:
10-Gigabit Ethernet: enter tengigabitethernet slot/port.
10-Gigabit Ethernet: enter tengigabitethernet slot/port.
Port channel: enter port-channel {1-512}.
If a downstream interface in an uplink-state group is disabled (Oper Down state) by uplink-state tracking because an upstream port is
down, the message error-disabled[UFD] displays in the output.
Display the current conguration of all uplink-state groups or a specied group.
EXEC mode or UPLINK-STATE-GROUP mode
(For EXEC mode) show running-config uplink-state-group [group-id]
Uplink Failure Detection (UFD)
1033