White Papers

Status: online
System Mac: a0:68:00:3f:92:bc
PE Up Time: 14:06:37
PE Discovery Status: Provisioned PE
User Configured Cascade Ports: Te 1/4(A)
Cascade LAG: Po 258, Local Status: Up, Remote Status: Up
PE Configuration: Local Status: Present, Remote Status: Present
---------------------------------------------------------------
Stack-id Status Reason Type UnitMac No. of Ports
---------------------------------------------------------------
0 online - C1048P a0:68:00:3f:92:bc 52
1 online - C1048P 6c:c0:00:11:22:33 52
2 online - C1048P 34:17:eb:00:bb:09 52
Adding a Unit to an Existing PE Stack
You can add a stack unit to an existing stack as follows:
1 Disconnect a stack cable from the stack’s ring topology. Re-attach the cable to a stacking port on the back panel of the new unit.
2 Attach a cable from the second stack port on the new unit to the stack port on a unit in the ring.
3 Power on the new unit.
After the new unit loads and the parent C9010 discovers it, the precongured software settings download from the C9010. The new unit
functions as part of the stack.
Renumbering a Stack Unit
By default, the number of a PE stack unit is 0. After you create and power on a PE stack, the units automatically number from 0 to 7,
starting at 0. To change the default or automatically assigned stack unit number, use the pe renumber command.
NOTE
: You can renumber a unit only when it is online and if no unit with the new stack-unit number is online.
Congure a stack-unit number.
EXEC Privilege mode
pe pe-id stack-unit unit-id renumber unit-id
Where:
pe pe-id is the PE ID number. The range is from 0 to 255.
stack-unit unit-id is the stack-unit ID number. The range is from 0 to 7.
renumber renumber is the new stack-unit ID.
Dell# pe 200 stack-unit 3 renumber 5
Renumbering the stack master triggers a stack reload, as shown in the following message. When the stack comes back online, the master
unit remains the management unit.
Renumbering management unit will reload the stack.
WARNING: Interface configuration for current unit will be lost!
Proceed[confirm yes/no]: yes
Port Extender (PE) Stacking
767