Product Data Sheet / Brochure

Table 21. Thermal restriction matrix (continued)
Configuration
8 x 2.5-inch
NVMe
16 x 2.5-inch
SAS/ SATA + 8 x
2.5-inch NVMe
12 x 3.5-inch SAS/
SATA
Ambient
temperature
Rear storage No Rear Drives No Rear Drives No Rear Drives
2U HPR HSK 2U HPR HSK 2U HPR HSK
NOTE: Fan blank is required to be installed in Fan 1 slot for five standard fan, and five high performance fan configurations.
One high-performance fan (Gold Grade) is required to be installed in Fan 1 slot when rear drives are installed.
NOTE: GPU is not supported in any of the configurations.
NOTE: OCP shroud is required if riser module is not installed.
NOTE: Processor blank is required for one processor configuration. DIMM blank is required in the CPU2 location
irrespective of the air shroud.
Table 22. Processor and heat sink matrix
Heat sink Processor TDP
2U STD HSK < 165 W
2U HPR HSK >= 165 W
Table 23. Label reference
Label Description
STD Standard
HPR (Silver) High performance (silver grade)
HPR (Gold) High performance (gold grade)
HSK Heat sink
LP Low profile
FH Full height
Technical specifications 15