Reference Guide

–vdkey:<VD FQDD>: The Virtual Drive to change the access to.
Example
racadm raid assignva:RAID.ChassisIntegrated.1-1-1 -
vdkey:Disk.Virtual.0:RAID.ChassisIntegrated.1-1 -accesspolicy
{ na | rw }
racadm raid assignva:RAID.ChassisIntegrated.1-1-2 -
vdkey:Disk.Virtual.0:RAID.ChassisIntegrated.1-1 -accesspolicy rw -
assignpolicy multiple
unblink
Description
Stops blinking or identifies an operation on the specified device.
Synopsis
racadm raid unblink:<PD FQDD>
racadm raid unblink:<VD FQDD>
racadm raid unblink {-pdkey:<comma separated PD FQDDs|-
vdkey:<comma separated VD FQDDs}
Input
–pdkey: A comma-seperated list of physical disk drive FQDDs to use in the operation.
–vdkey: A comma-seperated list of virtual drive FQDDs to use in the operation.
Example
racadm raid unblink:Disk.Bay.0:Enclosure.Internal.
0-0:RAID.ChassisIntegrated.1-1
racadm raid unblink:Disk.Virtual.0:RAID.ChassisIntegrated.1-1
racadm raid unblink -pdkey:Disk.Bay.0:Enclosure.Internal.
0-0:RAID.ChassisIntegrated.1-1,Disk.Bay.0:Enclosure.Internal.
0-0:RAID.ChassisIntegrated.1-1
racadm raid unblink -vdkey:Disk.Virtual.0:RAID.ChassisIntegrated.
1-1,Disk.Virtual.0:RAID.ChassisIntegrated.1-1
init
Description
Starts an initialization operation on the specified virtual drive.
Synopsis
racadm raid init:<VD FQDD> -speed {fast | full} {-current | -
pending}
Input
–current <optional>: Performs the configuration right now.
NOTE: If this requires the system to reboot it will reboot then.
–pending: Save the configuration change for a later application. You can use a combination
of the –pending and –current flags on multiple commands to reduce the possible number of
system reboots.
–speed{fast | full}: Perform a fast or full (slow) initialization on the virtual drive.
Example
racadm raid init:Disk.Virtual.0:RAID.ChassisIntegrated.1-1 -speed
fast
racadm raid init:Disk.Virtual.0:RAID.ChassisIntegrated.1-1 -speed
full
75