White Papers

PowerEdge VRTX
13
4. The Firmware Update Progress section displays the status of firmware update. A status indicator
displays on the page while the image file uploads. File transfer time varies on the basis of
connection speed. When the internal update process begins, the page automatically refreshes and
the Firmware update timer is displayed.
You must powercycle the chassis after performing update on Chassis Infrastructure Firmware.
Updating IOM Firmware
IOM Firmware updated is performed using the IOM user interface:
1. Copy the r2401-10052.ros files to a TFTP server.
2. Turn on the VRTX Chassis.
3. Make sure that the TFTP server is addressable on the CMC Ethernet segment.
4. Configure the ARC-II out-of-band port IP Address so that it is in the same network as the TFTP
server.
In this example, TFTP server IP address is 192.168.1.162, and ARC-II OOB is 192.168.1.167/24.
1. Connect to CMC using Telnet/SSL by using an Ethernet-based attachment.
2. Log in to the CMC and then type connect switch, at the login prompt enter the User Name and
Password (default is the CMC user name and password).