racadm setled -m server-9 -1 1
ERROR: Server in slot 9 is an extension of the server in slot 1.
setniccfg
Description Sets the iDRAC IP address. It displays an error message if the requested operation
could not be performed, or a success message, if the operation is completed
successfully.
To use this subcommand, you must have the Configure iDRAC permission.
NOTE: The terms NIC and Ethernet management port may be used interchangeably.
Synopsis
racadm setniccfg -d
racadm setniccfg -d6
racadm setniccfg -s <IPv4Address> <netmask> <IPv4
gateway>
racadm setniccfg -s6 <IPv6 Address> <IPv6 Prefix
Length> <IPv6 Gateway>
racadm setniccfg -o
Input
-d — Enables DHCP for the NIC (default is “DHCP disabled”.)
-d6 — Enables AutoConfig for the NIC. It is enabled by default.
-s — Enables static IP settings. The IPv4 address, netmask, and gateway can
be specified. Otherwise, the existing static settings are used. <
IPv4Address
>,
<
netmask
>, and <
gateway
> must be typed as dot-separated strings.
racadm setniccfg -s 192.168.0.120 255.255.255.0 192.168.0.1
-s6 — Enables static IPv6 settings. The IPv6 address, Prefix Length, and the
IPv6 gateway can be specified.
-o — Enable or disable NIC.
Example
racadm setniccfg -s 192.168.0.120 255.255.255.0
192.168.0.1
racadm setniccfg -d
racadm setniccfg -d6
setpciecfg
Description Configure PCIe slots and Virtual Adapters.
NOTE: To use this subcommand, you must have Chassis Administrator privilege.
NOTE: The slot assignment feature is licensed.
Synopsis
racadm setpciecfg assign [-c <FQDD>] [-i <server slot>]
racadm setpciecfg unassign [-c <FQDD>]
Input
-c — Use this option to specify a PCIe adapter or Virtual Adapter.
-I — Use this option to specify the slot number.
85