Messages Reference Guide

SubCategory CMC = Chassis Management Controller
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
CMC8509
Message Unable to activate the extended storage feature on the secondary CMC:
arg1
. The feature will
be deactivated.
Arguments
arg1 =
cmc number
Detailed
Description
The extended storage feature is not activated if the media on the secondary CMC is no longer
functional.
Recommended
Response Action
Do one of the following, and retry the operation: 1) In the CMC Web interface, go to Chassis
Controller > Flash Media > Configuration and verify if the card on the secondary CMC displays
errors. 2) Do a failover and then reprovision the card from the same GUI page. Reprovisioning
is only allowed on the card of primary CMC. However, if both the options 1 and 2 fail, the card
may be no longer functional.
Category Audit
SubCategory CMC = Chassis Management Controller
Severity Severity 1 (Critical)
Trap/EventID 8689
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#EMAIL Alert;#LC Log;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
CMC8510
Message Unable to activate the extended storage feature on the secondary CMC:
arg1
. The feature will
return to single CMC mode.
Arguments
arg1 =
cmc number
109