Messages Reference Guide

Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
CMC8542
Message The CMC
arg1
was restarted because of a manual reset.
Arguments
arg1 =
slot id
Detailed
Description
The CMC specified in the message was manually restarted.
Recommended
Response Action
No response action is required.
Category Audit
SubCategory CMC = Chassis Management Controller
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
CMC8543
Message The CMC
arg1
has reset because the thermal threshold was exceeded.
Arguments
arg1 =
slot id
Detailed
Description
The CMC specified in the message has reset becaused of thermal issues.
Recommended
Response Action
Do the following: 1) Review the Hardware Log and check if there are fans that are not
functioning properly. 2) Replace the fans that are not functioning properly. 3) If all the fans are
functioning, check the chassis temperature in the CMC Web Interface or by using RACADM.
When the fans are functioning properly and the chassis temperature is too high, the ambient
air temperture is too high or the air inlets are not receiving sufficient air.
Category Audit
SubCategory CMC = Chassis Management Controller
124