CMC8547
Message Missing kernel module
arg1
. Failover condition detected
Arguments
arg1 =
module name
Detailed
Description
A firmware error occurred causing the failover. If this condition continues, a failover will result.
If multiple failovers occur, contact Service.
Recommended
Response Action
No response action is required. If the issue persists, contact your service provider.
Category Audit
SubCategory CMC = Chassis Management Controller
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
CMC8548
Message Unable to communicate with peer CMC.
Detailed
Description
The local CMC has lost network connection with peer CMC for more than the timeout duration.
The timeout duration is 25 seconds for primary CMC and five seconds for secondary CMC.
After detecting the error, failover is performed if secondary CMC is available, otherwise CMC is
reset.
Recommended
Response Action
Make sure that the network cable is connected to the primary CMC. A Link loss was detected.