Messages Reference Guide

Category Storage
SubCategory ENC = Storage Enclosr
Severity Severity 1 (Critical)
Trap/EventID 4337
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
ENC4
Message
arg1
firmware mismatch.
Arguments
arg1 =
Enclosure Name
Detailed
Description
The firmware on the EMM modules is not the same version. It is required that both modules
have the same version of the firmware. This alert may be caused when you attempt to insert an
EMM module that has a different firmware version than an existing module.
Recommended
Response Action
Download the same version of the firmware to both EMM modules.
Category Storage
SubCategory ENC = Storage Enclosr
Severity Severity 2 (Warning)
Trap/EventID 4338
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
ENC5
Message Redundancy on
arg1
is degraded
Arguments
arg1 =
Enclosure Name
Detailed
Description
One or more of the enclosure components has failed. For example, a fan or power supply may
have failed. Although the enclosure is currently operational, the failure of additional
components could cause the enclosure to fail.
213