Messages Reference Guide

Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
HWC2015
Message The
arg1
is configured correctly.
Arguments
arg1 =
name
Detailed
Description
None.
Recommended
Response Action
No response action is required.
Category System Health
SubCategory HWC = Hardware Config
Severity Severity 3 (Informational)
Trap/EventID 2331
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
HWC5035
Message An over-temperature event detected on I/O module
arg1
.
Arguments
arg1 =
number
Detailed
Description
The I/O module over heated.
Recommended
Response Action
Do the following: 1) Make sure fans are installed and working correctly. 2) Check the
temperature sensor status for the chassis and make sure it is within the chassis operating
temperature range. 3) Reseat the I/O module to clear the over-temperature condition. If the
problem persists, contact the service provider.
Category System Health
SubCategory HWC = Hardware Config
Severity Severity 1 (Critical)
Trap/EventID 2329
288