Messages Reference Guide

Trap/EventID 4345
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
PDR47
Message A block on
arg1
was punctured by the controller.
Arguments
arg1 =
physical disk
Detailed
Description
The controller encountered an unrecoverable medium error when attempting to read a block
on the physical disk and marked that block as invalid. If the controller encountered the
unrecoverable medium error on a source physical disk during a rebuild or reconfigure
operation, it punctures the corresponding block on the target physical disk. The invalid block
clears on a write operation.
Recommended
Response Action
Back up the data from the disk. Start disk initialization and wait for it to complete, and then
restore the data from a backup copy.
Category Storage
SubCategory PDR = Physical Disk
Severity Severity 1 (Critical)
Trap/EventID 4345
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
PDR48
Message The
arg1
rebuild has resumed.
Arguments
arg1 =
physical disk
Detailed
Description
This message is generated after rebuild resumes on a physical disk.
Recommended
Response Action
No response action is required.
451