Messages Reference Guide

Recommended
Response Action
Assign a larger disk as the global hot spare.
Category Storage
SubCategory PDR = Physical Disk
Severity Severity 2 (Warning)
Trap/EventID 4346
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
PDR51
Message Hot spare
arg1
SMART polling has failed.
arg2
Arguments
arg1 =
physical disk
arg2 =
args
Detailed
Description
The controller firmware attempted to do SMART polling on the hot spare but could not
complete the SMART polling. The controller may have lost communication with the hot spare.
Recommended
Response Action
Verify the health of the disk assigned as a hot spare. Replace the disk and reassign the hot
spare. Make sure the cables are attached securely. See the storage hardware documentation
for more information on checking the cables.
Category Storage
SubCategory PDR = Physical Disk
Severity Severity 1 (Critical)
Trap/EventID 4345
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
PDR52
Message A redundant path is broken.
Detailed
Description
The controller has two connectors that are connected to the same enclosure. The
communication path on one connector has lost connection with the enclosure. The
communication path on the other connector is reporting this loss.
453