Messages Reference Guide

Category System Health
SubCategory AMP = Amperage
Severity Severity 1 (Critical)
Trap/EventID 2177
LCD Message Disk drive bay <name> current is outside of range. Contact Support
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
AMP0308
Message Disk drive bay
arg1
current is greater than the upper warning threshold.
Arguments
arg1 =
name
Detailed
Description
Product documentation contains information on correct configuration. The failure could also
be caused by a faulty component or related cabling. System performance may be degraded.
Recommended
Response Action
Review system power policy, check system logs for power related failures, and review system
configuration changes.
Category System Health
SubCategory AMP = Amperage
Severity Severity 2 (Warning)
Trap/EventID 2178
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
AMP0309
Message Disk drive bay
arg1
current is greater than the upper critical threshold.
Arguments
arg1 =
name
Detailed
Description
Product documentation contains information on correct configuration. The failure could also
be caused by a faulty component or related cabling. System performance may be degraded.
51