Messages Reference Guide

Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
PSU0007
Message Power supply
arg1
is operating at 110 volts, and could cause a circuit breaker fault.
Arguments
arg1 =
number
Detailed
Description
A power supply that is designed to operate at 220V, but is connected to a 110V power source
requires additional current for operation. The additional current may trip circuit-breakers or
cause other electrical issues with the input source.
Recommended
Response Action
Check input power source and cabling. Use recommended input power. Review the product
documentation. If the issue persists, contact technical support. Refer to the product
documentation to choose a convenient contact method.
Category System Health
SubCategory PSU = Power Supply
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
PSU0023
Message Power supply
arg1
operating at 110 volts has been acknowledged by user.
Arguments
arg1 =
number
Detailed
Description
None
Recommended
Response Action
No response action is required.
Category System Health
SubCategory PSU = Power Supply
Severity Severity 3 (Informational)
527