Messages Reference Guide

Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
PWR8595
Message Chassis Management Controller is unable to turn on server
arg1
due to insufficient power for
the
arg2
.
Arguments
arg1 =
slot id
arg2 =
chassis component name
Detailed
Description
The turn-on request for the server identified in the message did not succeed because of
insufficient power to the chassis component identified in the message.
Recommended
Response Action
The Chassis Management Controller (CMC) will retry turning on the server and the
corresponding components associated to the server after a predefined interval. If the issue
persists, refer to the Managing and Monitoring Power section in the CMC User Guide for more
information on configuring power management settings.
Category Audit
SubCategory PWR = Power Usage
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
PWR8596
Message Chassis Management Controller is unable to turn on server-
arg1
because PSU redundancy is
lost and the available power is insufficient.
Arguments
arg1 =
slot number
Detailed
Description
The Chassis Management Controller cannot turn on the server identified in the message,
because PSU redundancy is lost or PSUs are removed. Sufficient power is not avaiilable for the
operation.
Recommended
Response Action
Make sure there is enough power supply to distribute power. Go to, the Chassis Overview >
Power > Power Budget Status. In the Total Input Power Available For Allocation field, view the
available power. To add more power, insert more PSUs or remove unused components from
the chassis. When enough power is available, retry the operation.
595