Messages Reference Guide

Detailed
Description
The communication between the primary and standby CMCs was lost. This may occur when
the CMC identified in the message is restarting, or a firmware update operation is in progress.
If the issue persists, a failover will occur.
Recommended
Response Action
Wait for 10 minutes for: 1)Firmware update operations to complete and 2) The CMC to finish
restarting. If the communication is not reestablished, remove and reinsert the CMC.
Category Audit
SubCategory RDU = Redundancy
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
RDU8520
Message CMC
arg1
: recovered from unheathy state
Arguments
arg1 =
slot number
Detailed
Description
The standby CMC is recovered from unhealthy state by the monitoring daemon.
Recommended
Response Action
No response action is required.
Category Audit
SubCategory RDU = Redundancy
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
RDU8521
Message CMC
arg1
: active CMC has been removed
634