Messages Reference Guide

Category Storage
SubCategory BAT = Battery Event
Severity Severity 3 (Informational)
Trap/EventID 4275
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
BAT1031
Message The battery temperature on
arg1
is above normal.
Arguments
arg1 =
controller name
Detailed
Description
The room temperature may be too hot. In addition, the system fan may be degraded or failed.
Recommended
Response Action
Verify that the room temperature is normal and that fans are functioning properly. See the
storage hardware documentation for acceptable operating temperatures.
Category Storage
SubCategory BAT = Battery Event
Severity Severity 2 (Warning)
Trap/EventID 4274
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
BAT1032
Message The battery temperature on
arg1
is normal.
Arguments
arg1 =
controller name
Detailed
Description
The battery temperature is within the normal operating range.
70