Messages Reference Guide

Recommended
Response Action
If communications with the iDRAC is not functioning, reset the iDRAC and retry the operation
after a few minutes. Run the RACADM command "racadm ping server-<slot number> " to check
the communications. If the communications are not functional, restart the iDRAC by performing
a Virtual Reseat of the server using the RACADM command "racadm racreset -m server-<slot
id>".
Category Audit
SubCategory SWC = Software Config
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
SWC8530
Message Chassis Management Controller unable to set administrator access to the iDRAC root user.
Detailed
Description
The Chassis Management Controller is unable to set the server administrator access to the
iDRAC root user. This can happen if the communction to the iDRAC from CMC is non-functional
or the iDRAC is rebooting
Recommended
Response Action
If communications with the iDRAC is not functioning, reset the iDRAC and retry the operation
after a few minutes. Run the RACADM command "racadm ping server-<slot number> " to check
the communications. If the communications are not functional, restart the iDRAC by performing
a Virtual Reseat of the server using the RACADM command "racadm racreset -m server-<slot
id>".
Category Audit
SubCategory SWC = Software Config
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
SWC8531
Message Chassis Management Controller unable to set iDRAC administrator role for root user account.
773