Messages Reference Guide

44
TMP Event Messages
TMP8500
Message I/O Module
arg1
temperature exceeded operating range.
Arguments
arg1 =
iom slot name
Detailed
Description
The temperature of the I/O Module identified in the message has increased beyond the
operational range. Thermal protection shut down the I/O Module. Factors external to the I/O
Module may have caused this situation.
Recommended
Response Action
Check the chassis event log for fan issues and fix any issues present. If no fan issues are
detected, check chassis ambient temperature and make sure the temperature is within
operating range. Utilize the RACADM command "racadm getsensorinfo" to check the chassis
ambient temperature.
Category Audit
SubCategory TMP = Temperature
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
TMP8501
Message Unable to read planar board temperature sensors. The cooling has been increased to
safeguard the system.
Detailed
Description
System was unable to read planar board or control panel temperature sensors. The fan speed
was increased to protect system hardware.
Recommended
Response Action
Remove AC power from the system and reapply AC power. Check to see if the issue is
resolved. If the issue persists, contact your service provider.
Category Audit
SubCategory TMP = Temperature
819