Messages Reference Guide

Severity Severity 1 (Critical)
Trap/EventID 2169
LCD Message System board <name> voltage is outside of range. Contact support
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
VLT0205
Message The system board
arg1
voltage is within range.
Arguments
arg1 =
name
Detailed
Description
None
Recommended
Response Action
No response action is required.
Category System Health
SubCategory VLT = Voltage
Severity Severity 3 (Informational)
Trap/EventID 2171
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
VLT0206
Message The memory module
arg1arg2
voltage is less than the lower warning threshold.
Arguments
arg1 =
number
arg2 =
name
Detailed
Description
System hardware detected an over voltage or under voltage condition. If multiple voltage
exceptions occur consecutively the system may power down in failsafe mode.
Recommended
Response Action
1) Review system logs for power supply exceptions. 2) Reseat the memory module. 3) If the
problem persists, contact technical support. Refer to the product documentation to choose a
convenient contact method.
911