Messages Reference Guide

Category System Health
SubCategory VLT = Voltage
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
VLT0207
Message The memory module
arg1arg2
voltage is less than the lower critical threshold.
Arguments
arg1 =
number
arg2 =
name
Detailed
Description
System hardware detected an over voltage or under voltage condition. If multiple voltage
exceptions occur consecutively the system may power down in failsafe mode.
Recommended
Response Action
1) Review system logs for power supply exceptions. 2) Reseat the memory module. 3) If the
problem persists, contact technical support. Refer to the product documentation to choose a
convenient contact method.
Category System Health
SubCategory VLT = Voltage
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message Memory module <number> <name> voltage is outside of range. Contact support
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
VLT0208
Message The memory module
arg1arg2
voltage is greater than the upper warning threshold.
Arguments
arg1 =
number
arg2 =
name
912