Owner's Manual

238 Troubleshooting and Recovery
5
Select the component or components for which you want to enable LED
blinking.
6
Click
Apply
.
Using RACADM
Open a Telnet/SSH text console to the CMC, log in, and type:
racadm setled -m <
module
> [-l <
ledState
>]
where
<
module
>
specifies the module whose LED you want to configure.
Configuration options:
server-
n
where
n
=1–16
switch-
n
where
n
=1–6
cmc-active
and
<
ledState
>
specifies whether the LED should blink.
Configuration options:
0 — no blinking (default)
1 — blinking
Configuring SNMP Alerts
Simple network management protocol (SNMP) traps, or event traps, are
similar to e-mail event alerts. They are used by a management station to
receive unsolicited data from the CMC.
You can configure the CMC to generate event traps. Table 10-1 provides an
overview of the events that trigger SNMP and e-mail alerts. For information
on e-mail alerts, see "Configuring E-mail Alerts" on page 243.
Table 10-1. Chassis Events That Can Generate SNMP and E-mail Alerts
Event Description
Fan Probe Failure A fan is running too slow or not at all.
Battery Probe Warning A battery has stopped functioning.
Temperature Probe
Warning
The temperature is approaching excessively high or low
limits.