Owner's Manual

368 Using the LCD Panel Interface
Critical PCI System Err: Critical Event
sensor, PCI SERR (<Slot number
or PCI Device ID>) was asserted
PCI error detected by device.
Critical SBE Log Disabled: Event Log
sensor, correctable memory error
logging disabled was asserted
Single bit error logging is disable
when too many SBE get logged.
Critical Logging Disabled: Event Log
sensor, all event logging disabled
was asserted
All error logging is disabled.
Non-
Recoverable
CPU Protocol Err: Processor
sensor, transition to non-
recoverable was asserted
The processor protocol entered a
non-recoverable state.
Non-
Recoverable
CPU Bus PERR: Processor sensor,
transition to non-recoverable was
asserted
The processor bus PERR entered a
non-recoverable state.
Non-
Recoverable
CPU Init Err: Processor sensor,
transition to non-recoverable was
asserted
The processor initialization
entered a non-recoverable state.
Non-
Recoverable
CPU Machine Chk: Processor
sensor, transition to non-
recoverable was asserted
The processor machine check
entered a non-recoverable state.
Critical Memory Spared: Memory sensor,
redundancy lost (<DIMM
Location>) was asserted
Memory spare is no longer
redundant.
Critical Memory Mirrored: Memory sensor,
redundancy lost (<DIMM
Location>) was asserted
Mirrored Memory is no longer
redundant.
Critical Memory RAID: Memory sensor,
redundancy lost (<DIMM
Location>) was asserted
RAID Memory is no longer
redundant.
Critical Memory Cfg Err: Memory sensor,
configuration error (<DIMM
Location>) was asserted
Memory configuration is incorrect
for the system.
Table C-8. Server Status Screen for M600/M605 (continued)
Severity Message Cause