Owner's Manual

file:///T|/htdocs/SOFTWARE/smdrac3/cmc/cmc1.10/en/readme/CMC_1.10_A00_README.txt[10/26/2012 2:29:56 PM]
Hardware added.
* If a server module installed in a FlexAddress enabled slot contains a
Qlogic or Emulex mezzanine card that has a BIOS firmware revision that
is not the minimum version required, the server module BIOS will detect
the incompatibility and alert the user of the problem by changing the server
module health in the CMC to a red X. The FlexAddress Webpage for the
server module may incorrectly show green check marks next to the
chassis-assigned addresses for that module. The server module will use
server-assigned MAC addresses despite the indications on the FlexAddress
Webpage.
######################################################################
KNOWN ISSUES FOR BROWSERS
######################################################################
* In Internet Explorer Version 6, log data may not display and instead
only a message of, "Loading Chassis Event Log..." is shown .
Select Advanced Settings/Security and make sure the
option, "Allow active content to run in files on My Computer" is
NOT checked to fix this issue.
* In Internet Explorer Version 6, if the security setting is set to
restricted, the CMC User Interface on the Alert Management pages for
Email Alerts and SNMP Traps will display a Security Information
message that states that the page contains both secure and non-secure
items and will ask if you want to continue. Select "Yes". This message
is displayed because Internet Explorer Version 6 does not allow the use
of hidden IFRAMES on secure (SSL) pages. (183022)
######################################################################
KNOWN ISSUES FOR CMC
######################################################################
* The Chassis Asset Tag information is incorrectly displayed in the
Service Tag field on the Chassis LCD (218411)
* RACADM CLI based command-line tool uses TFTP to transfer image files
for all firmware updates. Only the default port for TFTP (69) is
supported for transfers with version 1.0. (157754)
* Clearing the CMC Log can take a long time. Allow up to
one (1) minute for this operation to complete.(152860)
* If the CMC is on a private network without access to the Internet
and you are using Internet Explorer 6 SP 2 or Internet Explorer 7,
you may experience delays of up to 30 seconds when using remote
RACADM commands. (161019)
* In the CMC User Interface, under Chassis -> Network/Security tab->
Network subtab, if the network speed is set to 1GB to match your
network environment then the CMC will revert to Auto Negotiation
internally to determine the network speed and Duplex Mode. It will
not use the values set.(180871)