Owner's Manual

file:///T|/htdocs/SOFTWARE/smdrac3/cmc/cmc1.10/en/readme/CMC_1.10_A00_README.txt[10/26/2012 2:29:56 PM]
there will be no error message indicating the failure of this operation.
Upload the valid image and restart the firmware update operation. (186170)
* If the standby CMC firmware was previously updated and then later
made active, you will see an entry in the CMC log (raclog) that
states the firmware update was successful, but with the most recent time
stamp. This is because the standby CMC cannot register its entries to the
logs until it becomes active. (186858)
#####################################################################
KNOWN ISSUES FOR USER INTERFACE ONLINE HELP
#####################################################################
This section provides additional information about known issues with
the CMC Firmware version 1.0 User Interfaces online help.
* The help for the Services Management page located in the Chassis->
Network/Security tab->Services sub-tab of the CMC user interface in
localized languages do not list the Telnet Port legal values.
(179080)
* The help for the Slot Names page located in the Chassis-> Servers ->
Setup->Slot Names sub-tab of the CMC user interface in localized
languages do not list the rules for the slot names, which are:
(a) The beginning of the string cannot be Switch-, Fan-, PS-, KVM,
DRAC/MC-, Chassis and Housing-Left/Right/Center, which are case
insensitive.
(b) ASCII characters between 32 and 126 are allowed, but excludes 34 (").
(c) Server-n, where n is 1 to 10, is not allowed except that Server-n is
allowed for the n slot, which is case insensitive. Server-0n
is different from Server-n, like Server-02 is different from
Server-2. Therefore Server-2 is not allowed for any slot except the second
one but Server-02 can be set in any slot. (178014)
(d) Maximum allowed characters for the Slot Name is 15. (181364)
* The help for the Server Status page located in the Chassis-> Servers
->Server 1-16 -> Properties tab->Status sub-tab of the CMC user
interface in localized languages does not list the Slot Name, Present
properties. It also has a reference to I/O module instead of servers under Health
-> Informational section. (179718)
* The help for the Chassis Power Management page located in the
Chassis-> Power Management tab->Control sub-tab of the CMC user interface in
localized languages refers to Power Off System as equivalent to pressing
the power button when the power is "ON". This is not accurate since
this action performs a graceful shutdown of the chassis and if any of the
modules do not shutdown within the time period, they will remain on. (181069)
* The help for the Identify page located in the Chassis-> Troubleshooting
tab->Identify sub-tab of the CMC user interface in localized languages
mentions the note:
To blink or unblink the servers, you must have Log in to iDRAC
privilege on the iDRAC of these servers.