User's Manual

392 Using the LCD Panel Interface
LCD Error Messages
Table C-2. CMC Status Screens
Severity Message Cause
Critical CMC <number> Battery: Battery
sensor for CMC, failed was
asserted
CMC CMOS battery is missing or
no voltage.
Critical CMC <number> CPU Temp:
Temperature sensor for CMC,
failure event
CMC CPU temperature exceeded
the critical threshold.
Critical CMC <number> Ambient Temp:
Temperature sensor for CMC,
failure event
CMC Ambient temperature
exceeded the critical threshold.
Table C-3. Enclosure/Chassis Status Screen
Severity Message Cause
Critical Chassis Fan <number> Presence:
Fan sensor for Chassis Fan, device
removed was asserted
This fan is required for proper
cooling of the enclosure/chassis.
Warning Power Supply Redundancy: PS
Redundancy sensor for Power
Supply, redundancy degraded was
asserted
One or more PSU have failed or
removed and the system can no
longer support full PSU
redundancy.
Critical Power Supply Redundancy: PS
Redundancy sensor for Power
Supply, redundancy lost was
asserted
One or more PSU have failed or
removed and the system is no
longer redundant.
Critical Power Supply Redundancy: PS
Redundancy sensor for Power
Supply, non-redundant:
insufficient resources
One or more PSU have failed or
removed and the system lacks
sufficient power to maintain
normal operations. This could
cause servers to power down.
Critical Control Panel Temp: Temperature
sensor for Control Panel, failure
event
Chassis/Enclosure temperature
exceeded the critical threshold.