User's Manual

396 Using the LCD Panel Interface
Critical Mezz B <slot number> Status:
Add-in Card sensor for Mezz B
<slot number>, install error was
asserted
Incorrect Mezzanine card installed
for I/O fabric.
Critical Mezz C <slot number> Status:
Add-in Card sensor for Mezz C
<slot number>, install error was
asserted
Incorrect Mezzanine card installed
for I/O fabric.
Critical Backplane Drive <number>:
Drive Slot sensor for Backplane,
drive removed
Storage Drive was removed.
Critical Backplane Drive <number>:
Drive Slot sensor for Backplane,
drive fault was asserted
Storage Drive failed.
Critical System Board PFault Fail Safe:
Voltage sensor for System Board,
state asserted was asserted
This event is generated when the
system board voltages are not at
normal levels.
Critical System Board OS Watchdog:
Watchdog sensor for System
Board, timer expired was asserted
The iDRAC watchdog timer
expires and no action is set.
Critical System Board OS Watchdog:
Watchdog sensor for System
Board, reboot was asserted
The iDRAC watchdog detected
that the system has crashed (timer
expired because no response was
received from Host) and the action
is set to reboot.
Critical System Board OS Watchdog:
Watchdog sensor for System
Board, power off was asserted
The iDRAC watchdog detected
that the system has crashed (timer
expired because no response was
received from Host) and the action
is set to power off.
Critical System Board OS Watchdog:
Watchdog sensor for System
Board, power cycle was asserted
The iDRAC watchdog detected
that the system has crashed (timer
expired because no response was
received from Host) and the action
is set to power cycle.
Table C-8. Server Status Screen (continued)
Severity Message Cause