User's Manual

Using the LCD Panel Interface 397
Critical System Board SEL: Event Log
sensor for System Board, log full
was asserted
The SEL device detects that only
one entry can be added to the SEL
before it is full.
Warning ECC Corr Err: Memory sensor,
correctable ECC (<DIMM
Location>) was asserted
Correctable ECC errors reach a
critical rate.
Critical ECC Uncorr Err: Memory sensor,
uncorrectable ECC (<DIMM
Location>) was asserted
An uncorrectable ECC error was
detected.
Critical I/O Channel Chk: Critical Event
sensor, I/O channel check NMI was
asserted
A critical interrupt is generated in
the I/O Channel.
Critical PCI Parity Err: Critical Event
sensor, PCI PERR was asserted
Parity error was detected on the
PCI bus.
Critical PCI System Err: Critical Event
sensor, PCI SERR (<Slot number
or PCI Device ID>) was asserted
PCI error detected by device.
Critical SBE Log Disabled: Event Log
sensor, correctable memory error
logging disabled was asserted
Single bit error logging is disable
when too many SBE get logged.
Critical Logging Disabled: Event Log
sensor, all event logging disabled
was asserted
All error logging is disabled.
Non-
Recoverable
CPU Protocol Err: Processor
sensor, transition to non-
recoverable was asserted
The processor protocol entered a
non-recoverable state.
Non-
Recoverable
CPU Bus PERR: Processor sensor,
transition to non-recoverable was
asserted
The processor bus PERR entered a
non-recoverable state.
Non-
Recoverable
CPU Init Err: Processor sensor,
transition to non-recoverable was
asserted
The processor initialization
entered a non-recoverable state.
Table C-8. Server Status Screen (continued)
Severity Message Cause